Functioning
The power supply to the generator is indicated by the green LED. Until the required ambient temperature is achieved, the contact of the regulator remains in position 2-1 and the heating device is active. Once the set value is achieved, the contact shifts into position 2-8 and the heating or ventilation device is turned off. Any drop in temperature by the hysteresis value will activate the heating device again (contacts 2-1 closed) until the set temperature value is achieved.
| RT probe |
|
| design for | RT-820, RT-821, RT-822 |
| temperature sensor | KTY 10-6 |
| probe dimensions | Ø5; h=20mm |
| sensor silolation | thermoshrinkable shirt |
| cable | OMY 2×0,34mm²; l=2,5m |
| RT823 probe |
|
| design for | RT-823 |
| temperature sensor | KTY 10-6 |
| probe dimensions | Ø8; h=40mm |
| sensor silolation | brass muff |
| cable | SIHF 2×0,5mm²; l=2,5m heatresist |